Mobile Container Boiler/Transportable Container Boiler-Mobil
black">Transportable container boiler can be fully automatic operation. Transportable Container boiler display instrumentation and control systems are fixed in container which equipped with lights, doors, windows, pipes and other facilities. With fast-moving features, available motor transport to the site using a variety of complex such as oil, road construction sites, bridges, construction sites, mobile units, field work and other needs of the boiler areas. A fully furnished container auxiliary boiler, installed in place is simple, rapid, user-to-use site by simply assembling the water supply, gas pipeline and power. Look neat and beautiful, durable.For example:Transportable Container boiler parameter:
|
Boiler model
|
WNS1.5-0.7-Y(Q)
|
WNS2-1.25-Y(Q)
|
|
Nominal evaporation T/h
|
1500
|
2000
|
|
Nominal working pressure Mpa
|
0.7
|
1.25
|
|
Nominal steam temperature ℃
|
169
|
194
|
|
Design efficiency %
|
89
|
89
|
|
Light oil kg/h
|
108
|
150
|
|
Heavy oil kg/h
|
115
|
156
|
|
City gas Nm3/h
|
256
|
357
|
|
Natural gas Nm3/h
|
128
|
178
|
|
Main steam valve seat mm
|
DN65
|
DN80
|
|
Feed water tube diameter mm
|
DN25
|
DN25
|
|
Blowdown tube diameter mm
|
DN40
|
DN40
|
|
Safety valve tube diameter mm
|
2-DN40
|
2-DN40
|
|
Chimney diameter mm
|
350
|
350
|
|
Length mm
|
3300
|
3700
|
|
Width mm
|
1700
|
2000
|
|
Height mm
|
2100
|
2100
|
Tag: Steam Boiler, container boiler, Transportable Container boiler, gas(oil) fired boiler,